# IndeeHub worker image runtime qualification — 2026-10-08
Status: isolated actual-image shutdown qualification passed; live delivery remains open.
Source: `29627fc3a316316e5f75fe799218ff41a2a0dea8`.
Image: `9b3ef4116d4b998820e25e09eda7ca14f23e9e264158629451b81e32b47d9c8e`.
OCI archive SHA256: `6db29188c0e68ed8e9e8d84ea2e9c5c70695518e0930775bf6b3200d14d99527`.
Manifest: `sha256:b17a140356f3c78204668aa385bd1d7bae2c946ac85cc0688e650f618a19fbfa`.
The built image ran its unchanged production worker command against synthetic
Redis, PostgreSQL tables and a minimal S3 HTTP fixture in a shared network-none
namespace. No host ports, real credentials, live data mounts or payments were
used. The fixture generated one second of blue video and audio.
- Idle worker received SIGTERM and exited 0.
- Active job download was held open. SIGTERM followed by SIGINT did not terminate
it prematurely. After release it uploaded a 220-byte HLS manifest and a
19,744-byte encrypted segment, stored exactly one content key and marked the
first content completed. Worker exited 0.
- The queued successor remained waiting and its content remained pending.
- Installed runtime: Alpine 3.23.4, FFmpeg 8.0.1, Node 20.20.2.
- All five owned fixture containers were confirmed stopped. The exact container
IDs, image identities, namespaces and volume boundaries are retained.
Cold fixture database initialization exceeded the original 90-second harness
allowance. Stopping during initialization left a valid cluster without the
requested dummy database. The next failed setup receipt is also retained. The
missing synthetic database was explicitly created before worker tests; the
harness allowance became 300 seconds. This is fixture setup, not PostgreSQL
startup or recovery acceptance. No production deadline changed.
Evidence directory:
`~/.local/state/archipelago/release-qualification/worker-runtime-29627fc-20261008/`
It contains runtime-receipt.json, qualification-boundary.json, both setup failure
receipts, image-source.json, container logs, and exact hashed Python/JavaScript
harnesses. Redis/PostgreSQL were selected from the retained legacy-images.tar;
their config SHA256 and every uncompressed layer digest were verified before
loading into the separate private build store. The original worker build receipt
still records runtimeQualified=false at build time; this later receipt records
the additional evidence without rewriting history.
This qualifies shutdown with real BullMQ/Redis, PostgreSQL and FFmpeg on synthetic
media. It does not qualify real MinIO behavior, deployment, production migration,
full-length media, producer payments, timed rentals or discovery. Scoped Yaya
image import and reviewed signed catalog inclusion remain gated by the IndeeHub
cutover/recovery acceptance work. No live image import or publication occurred.